Get a quote

Calibration & services

Know how far out your thermometer is, on paper

Free quotes from calibration labs across South Africa. One request, no obligation.

A dry block calibrator with steel probes in its wells beside a liquid bath on a lab bench in Stellenbosch
ISO 17025Lab accreditation standardTraceable certificateHOLD

At a glance: Thermometer CalibrationIR THE 371

Suits
Probes, guns, cameras, loggers and sensors
How it works
Compared with a traceable reference
Range or size
Points from below freezing to furnace heat
Check first
ISO/IEC 17025 and the lab's SANAS scope
Lead time
Often about a week in the lab, ask

A thermometer that reads two degrees out can pass bad food, spoil a batch or fail an audit, and you would not know from looking at it. Thermometer calibration compares your instrument with a reference of known accuracy and records the difference, and the uncertainty of that comparison, on a certificate. Labs calibrate probe thermometers, infrared guns, thermal cameras, data loggers, thermocouples and PT100 sensors, in their lab or on your site. This page explains accreditation, methods, test points and intervals. Send one request and independent calibration labs that serve your area quote you directly.

What a calibration certificate tells you

A proper certificate lists each test point, what the reference read, what your instrument read, the error and the measurement uncertainty. It names the reference equipment and shows that it is itself traceable, through a chain of calibrations, to the national measurement standards kept by NMISA, the National Metrology Institute of South Africa. If the lab adjusted the instrument, a good certificate shows the readings before and after. A sticker with a date and a pass mark is not a certificate. Read the errors against your own tolerance: a probe that is 0.8 °C out may be fine for a braai and not fine for a pharmaceutical cold room.

Accredited or not, and why auditors care

ISO/IEC 17025 is the international standard for calibration and testing labs. In South Africa, SANAS (the South African National Accreditation System) assesses labs against it and publishes a scope of accreditation for each one, showing which instruments, ranges and uncertainties it covers. Auditors for ISO 9001, food safety schemes, pharmaceutical good practice and mining usually ask for accredited certificates. A non-accredited calibration can still be useful for internal checks, but ask whether your auditor will accept it, and check that the lab's scope covers your instrument and range, not just temperature in general.

How different instruments are calibrated

Contact probes, thermocouples and PT100 sensors go into a stirred liquid bath or a dry block calibrator next to a reference probe. Infrared thermometers and thermal cameras are aimed at a blackbody source, a target of known emissivity held at a set temperature. Data loggers are usually placed in a chamber or bath and their records compared with the reference. The test points should match how you use the instrument: for a kitchen probe, perhaps 0, 75 and 100 °C; for a vaccine fridge logger, points around 2 to 8 °C.

How often, and in the lab or on site

Many quality systems set a yearly interval, but the interval is yours to set, based on how hard the instrument is used, how stable it has been and what your auditor expects. Between calibrations, simple checks catch problems early: a probe in iced water should read close to 0 °C. Sending instruments to a lab often takes about a week, so plan spares. On site calibration suits fixed sensors, ovens and plants that cannot release their instruments, and saves the courier risk. Ask the lab which methods it can bring to you.

What to put in your request

  • Each instrument: type, range and serial number
  • The test points you need, for example 0, 75 and 100 °C
  • Whether you need SANAS accredited certificates
  • Lab or on site, and how many instruments on site
  • When the audit is or when the old certificates expire

Thermometer Calibration for industry, food, health, labs and homes

  • Factories, mines and plants: process probes, thermocouples and pyrometers calibrated on site during a shutdown
  • Kitchens, butcheries and food factories: kitchen and factory probe thermometers calibrated before the food safety audit
  • Hospitals, clinics and pharmacies: vaccine fridge loggers and clinical thermometers checked against a reference
  • Electricians, HVAC and refrigeration technicians: temperature guns and multimeter probes checked so readings hold up on the job
  • Labs, schools and universities: reference thermometers and PT100 probes calibrated with accredited certificates
  • Cold stores and distributors: cold room loggers and alarm sensors calibrated around 2 to 8 °C and -18 °C
  • Farms, poultry houses and packhouses: incubator, dairy and poultry house thermometers and hygrometers checked yearly
  • Households and families: a good cooking or pool thermometer checked when its readings seem off
  • Property managers, inspectors and security: building management sensors and HVAC probes calibrated for maintenance records

Frequently asked questions

Can I check my own thermometer between calibrations?
Yes, and many food safety plans ask for it. Fill a glass with crushed ice and a little water, stir and let it settle, then hold the probe in the middle: it should read close to 0 °C. Boiling water reads about 100 °C at the coast but only about 94 to 95 °C in Johannesburg. It is a useful check, not a calibration.
What happens if my instrument fails?
The lab records the error. Many instruments can be adjusted and checked again, which should show on the certificate as readings before and after. If it cannot be adjusted, or the error is too large, it may need a repair or a replacement. It is also worth looking back at what was measured with it since its last good calibration.
How do I know a lab is really accredited?
Ask for its SANAS accreditation number and look up its scope of accreditation on the SANAS website. The scope lists the quantities, ranges and uncertainties the lab is accredited for. Work outside that scope does not count as accredited, even if the same lab does it.
Do you calibrate instruments yourselves?
No. We are a free quote request service. We pass your request to independent calibration labs that serve your area and they quote you directly. We do not calibrate, adjust or certify anything ourselves. See about us.

Thermometer Calibration by province and city

More thermometers, cameras and services

Free quote request, no obligation

Request quotes for thermometer calibration

Describe it the way a technician would: how far away you stand and how big the target is, or the camera and the distance, or simply how many. The planner draws the measuring cone or the camera's view as you type. Suppliers and service companies in your area quote you directly.

Measurement sheet and quote requestThermometer Calibration
Req
64380
Date
2026-11-18
Cost
FREE

1The job

2How many (optional, it helps the quote)

YOUR REQUESTROUGH, NOT TO SCALE

-
-
-
-
-
-
Estimate
-

Plain geometry for the request, not a measurement.

3Where you are now

4Your list (optional)

  1. 01
  2. 02
Up to 12 lines: instruments, probes, certificates or services.
Needs and options

5Your details

Free and no obligation. By sending you agree that we may share your request with suitable suppliers and service companies. See our privacy policy.

Get a free quote